DualCom Pro

Dimensions 75 mm (h) x 119mm (w) x 15mm (d) or 75mm (h) x 119mm (w) x
32mm (d) with secondary radio module
Weight 113g excluding aerial
Temperature -10 °C to + 55 °C
Humidity 0 - 90% non-condensing
Mounting

Via fixing points under main cover

Warranty Please refer to our terms and conditions.
Power Requirement

10 - 36 Volts DC

In order to maintain compliance with requirements for electrical safety the Dualcom Pro should always be powered from a fused supply with following rating:

  • For a 12v DC system (supply voltage in the range 10vdc to 14vdc) a fuse rated at 1.25
  • For a 24v DC system (supply voltage in the range 20vdc to 36vdc) a fuse rated at 600 mA

If the power source is not limited to these values, then a fuse with the correct rating must be fitted in line with the positive connection from the power source.

Current Consumption DigiAir Pro = 35mA (Avg. Value)
GradeShift Pro - LAN/Radio = 40mA (Avg. Value)
GradeShift Pro - Radio/Radio = 175mA (Avg. Value)
Radio Path 2G, 3G, 4G
Aerial 50 ohm (nominal) on MMCX socket
Operation Method Store and forward
Input Terminals Max +30v, Min 0 volts DC (reference supply 0v supply) 100k
Low Battery 7.6V DC +/- 0.5 VDC
RCT Protocols SIA
User Serviceable Parts There are no serviceable parts within the DualCom Pro Range
Environmental Class II
Applicable Standards Suitable for use in alarm systems complying to:
EN50131-1:2006+A2:2017
EN50131-10:2014 Type Y
EN50136-1:2012+A1:2018 SP1,SP2,SP3,SP4,DP1,DP2,DP3,DP4
EN50130-5
Emissions Standard – 2014/53/EU (RED)
PD6662:2017 / PD6669:2017
ATS Classification: EN50136 ATS5/DP4 Max
ATS 5 parameters: D3/M3/T4/S2/I3/A3