The New Standards

Everything you need to know

There have been significant changes to alarm signalling standards and terminology. Grades 2, 3 and 4 now have Single Path (SP) and/or Dual Path (DP)  equivalents. The catastrophic failure reporting times have also changed. The DualCom Pro 2 Range operates to these standards and in some cases exceeds them.
This is how the old and new standards apply to current CSL products:

Before 1st June 2019 - Old ATS Grade (EN50136-1:1998)

ATS Grade Catastrophic Failure Reporting
Grade 2 25 hours
Grade 3 60 mins
Grade 4 6 mins

From 1st June 2019 - Single Path (SP) or Dual Path (DP) Equivalent (EN50136-1:2018/PD6669:2017/PD6662:2017)

Single Path (SP) Dual Path (DP) Catastrophic Failure Reporting
SP2 DP1 25 hours
DP2 31 mins
DP2+ 11 mins
DP3 4 mins
DP4 3 mins

The DualCom Pro 2 Range

Product Paths EN SP & DP Classes Catastrophic Failure Reporting
MiniAir 2 Radio Only SP2 12 hours
DigiAir Pro 2

Radio Only

LAN Only

SP2  25 hours
DigiAir Pro 2 Fire Radio Only SP3 31 mins
GradeShift Pro 2  Radio + Radio
LAN + Radio
DP2 31 mins
GradeShift Pro 2 Fire Radio + Radio DP2 31 mins
GradeShift Pro 2 Radio + Radio
LAN + Radio
DP2+ 11 mins
GradeShift Pro 2 Radio + Radio
LAN + Radio
DP3 4 mins
GradeShift Pro 2 LAN + Radio DP4 3 mins

 
If you would like to discuss any of these changes or investigate the option of upgrading to the new DualCom Pro 2 Range please contact us today.