Panel Connection – Dial Capture

Manufacturer Honeywell
Model Galaxy Classic Range
Minimum Panel Firmware 4.5 and above
Cable required?

MCM connected to

  • DualCom Pro 1 - MCM plug-on module CS.1.402
  • DualCom Pro 2 - DI & AL
Panel Profile Honeywell-Galaxy-MCM
Panel Connection Dial Capture
Technical Notes

 
DualCom Pro to Panel Wiring

DualCom Pro 1 - MCM plug-on module - Line A
DualCom Pro 2 - DI
PSTN A
DualCom Pro 1 - MCM plug-on module - Line B
DualCom Pro 2 - AL
PSTN B


Panel Config

  • Enter Engineering Mode - Menu 56
  • Select Internal Telecoms (Option 1)
  • Select Format (Option 1)
  • Enter SIA (Option 2)
  • Select SIA level 3
  • Turn on reporting triggers as needed (recommend 10 and 18)
  • Select Tel No.1 (option 2)
  • Set a dummy phone number, for example 01234 567890
  • Select Account Number (option 3)
  • Enter ARC Connection ID – see My Base
  • Go to Remote Access (Option 12)
  • Select Access Period – 4 Anytime
  • Select Mode 1 – Direct Access
  • Escape to return to Engineering Mode
  • Exit Engineer Mode into Day Mode