Panel Connection – Dial Capture
Manufacturer | Honeywell |
Model | Galaxy Classic Range |
Minimum Panel Firmware | 4.5 and above |
Cable required? |
MCM connected to
|
Panel Profile | Honeywell-Galaxy-MCM |
Panel Connection | Dial Capture |
Technical Notes |
DualCom Pro to Panel Wiring
DualCom Pro 1 - MCM plug-on module - Line A DualCom Pro 2 - DI |
PSTN A |
DualCom Pro 1 - MCM plug-on module - Line B DualCom Pro 2 - AL |
PSTN B |
Panel Config
- Enter Engineering Mode - Menu 56
- Select Internal Telecoms (Option 1)
- Select Format (Option 1)
- Enter SIA (Option 2)
- Select SIA level 3
- Turn on reporting triggers as needed (recommend 10 and 18)
- Select Tel No.1 (option 2)
- Set a dummy phone number, for example 01234 567890
- Select Account Number (option 3)
- Enter ARC Connection ID – see My Base
- Go to Remote Access (Option 12)
- Select Access Period – 4 Anytime
- Select Mode 1 – Direct Access
- Escape to return to Engineering Mode
- Exit Engineer Mode into Day Mode