Panel Connection – Serial
Manufacturer | DSC |
Model | Maxsys |
Version | 4020 |
Minimum Panel Firmware | V3:5 |
Cable required? | CS.1.207 |
Panel Profile | DSC-MAXSYS4020-RS232 |
Panel Bus Connection | RS232 |
Technical Notes |
Please see below |
Panel Connection Information
Manufacturer | Panel | Connection | Cable/Plug On | Supplied Cables |
DSC | PC Range | RS232 | 4 Pin | Green - RTN Blue - RS232-R Red - RS232-T |
Panel Programming
- Engineer login and set-up: 1. Press *8
- Keypad displays ‘Enter Your Installer Code’
- Press 5555
- Scroll to (00) System Area and press *
- Scroll to (03) DLS Section and press *
- Scroll to (00) DLS Toggles and press *
- Set DLS Enabled = Y
- Press # twice
- Scroll to (04) Communicator and press *
- Scroll to (00) Main Items and press *
- Scroll to (00) 1st Number and press *
- Scroll to (00) Pgm Tel Number and press *
- Set to CAAA and remove ‘D’ from the beginning
- Scroll to (01) Comms Format and press *
- Set to SIA Fsk Format
- Scroll to (02) Dialer Direction and press *
- Toggle events to be sent.
- Press # twice.
- Scroll to (03) System Account and press *
- Set Account Code, normally same Site ID as SPT
- Press # until you are back to step 9) and clear 2nd and 3rd telephone number, then
step 22) - Scroll to (01) Communications options (CommsToggles) and press *
- Set Communicator Enabled = Y
- Set TLM Enabled = N
- Set Automatic SIA codes (AutoReport SIA) = Y
- Set TLink Enabled = Y