Panel Connection – RS232 

Manufacturer Carrier
Model ATS Advisor Master plus serial plug on module
Version N/A
Minimum Panel Firmware Please refer to panel manufacturer
Cable required? See photo
Panel Profile ARITECH-ADVISOR-RS232
RS232
Technical Notes See below

Panel Connection Information

Connection Panel
RS232-T RXD
RS232-R TXD
RTN GND
CTS A+


    Panel Programming

    Menu 9 - Communications menu

    • PBX [not set]
    • MSN [not set]
    • DT Detection [UK]
    • DTMF tone dialling [Yes]
    • Enable PSTN line fault monitor [No]
    • Monitor service tones [No]
    • 3 digit SIA extensions [Yes]
    • ISDN point to point [No]
    • Enable ISDN line fault monitor [No]
    • 3 digit SIA extensions [Yes]
    • 200 baud reverse area open/close [No]
    • X25 TEI value [2]
    • Audio listen in time [180]
    • Audio listen in frame time [30]
    • Report mains fault [Yes]
    • Report line fault [Yes]
    • Enable GSM line fault monitor [No]
    • Central station
    • CS No <1> Enter
    • Format No: (Option 7)
    • Ph1
    • Ph2 [not set]
    • Acc No: system account number
    • Acc No: area 1 account number
    • Bell modem: [Yes]
    • Dual reporting [No]
    • Listen in [No]
    • Disable reporting inhibits [No]
    • Reserved [No]
    • XSIA Max characters [30]
    • X25 account code not important
    • Conn type (Option 4)
    • suppress FTC for voice reporting [No]
    • Retry count [10]
    • SIA Area Modifier [Yes]
    • X25 D-bit [No]
    • Mains Fail Reporting delay [30]
    • Enable IP Line Fault Monitor [No]
    • AWDGP reporting codes for IMQ [No]

    Menu 29 - Computer Connections menu

    • Enable Remote UpDownload [Yes]
    • Up/Download if any area armed [Yes]
    • Enable Remote Control [Yes or No]
    • Remote Control if any area armed
    • Use modem Init [No]
    • Report Alarms to computer [No]
    • Report Access to computer [No]
    • Cmp, Cbk, Srv
    • Computer Address [0001]
    • Security Password [0000000000]
    • Security Attempts [255]
    • Number of Rings [1]
    • Number of Calls [0]
    • Answer Machine [No]
    • Reserved [No]
    • Bell Modem [No]
    • Conn Type * (Option 4)
    • PC connections authorised [No]

    Troubleshooting

    • Note for ATS 2000 panels set the connection type here as PSTN. Rather than serial interface. The connection type in menu 9 needs to remain as Universal Interface.
    • *Please note without 12V to the CTS connection on the serial interface the serial board will not operate.