Panel Connection – Dial Capture

Manufacturer Carrier
Model Aritech ATS Advanced
Version N/A
Minimum Panel Firmware N/A
Cable required?

MCM connected to

  • DualCom Pro 1 - MCM plug-on module CS.1.402
  • DualCom Pro 2 - DI & AL
Panel Profile ARITECH-ADVANCED-MCM
Panel Bus Connection Dial Capture
Technical Notes

To enter engineer mode, access must be allowed via a setting in User mode. After defaulting the panel, the panel will ask questions on power up.

User Code : Menu 8:2:1 - Need Acc [YES]

Eng Code : Menu 8: Sys Opt > 7: Panel & AB Opts > 9: Remote Config - YES

Panel Connection Information

DualCom Pro 1 - MCM plug-on module - Line A
DualCom Pro 2 - DI
PSTN A
DualCom Pro 1 - MCM plug-on module - Line B
DualCom Pro 2 - AL
PSTN B

    Panel Programming

    • Enter : Installer Mode (Engineer)
    • Select: 9>Dialler menu
    • Enter: 1> CS
    • Enter: 01> CS 1
    • Set: CS name [CS 1]
    • Enter: 2>‘Transm Path’ [PSTN]
    • Enter 3>‘Protocol’
    • Set: (X)SIA’
    • Enter 4>Phone [01234567890]

    • Enter 5>‘Accounts’ menu
    • Select: ‘Area ‘1’ with [account numbers]
    • Select: ‘Area ‘2’ with [account numbers OR blank]
    • Select: ‘Area ‘3’ with [account numbers OR blank]
    • Select: ‘Area ‘4’ with [account numbers OR blank]

    • Enter 6>‘Mode’
    • Set: Primary CS’
    • Enter 7> retry count [10]

    • Enter 8>‘Protocol opt’
    • Set: ‘(X)SIA’
    • Set ‘Area Modifier’ to ‘[ON]’
    • Set ‘Name Chars’ to ‘[30]’
    • Set ‘Event Number’ to ‘[3 digits]’
    • Set ‘Subev codeing’ to ‘[Decimal]’
    • Set ‘SIA Frequency’ to ‘[Bell]’

    • Go back to ‘Dialler’ menu level
    • Enter 3>‘Path Options’
    • Enter 1>‘PSTN’
    • Enter 2>‘Line Fault’ menu and select option ‘[No]’
    • Go back to ‘Path Options’ menu level.
    • Enter 4>IP (If present)
    • Enter ‘Line Fault’ menu and select option ‘[No]’

    • Enter 4>‘PC Conn’ menu
    • Select 1>‘PC Conn 1’
    • Set 2>‘Trans Path’ to ‘PSTN’
    • Set 3>‘Modem Protocol’ to ‘V22’
    • Set 4>‘Phone Number’ to ‘None’ or blank
    • Set 5>‘Retry Timeout’ to ‘3’
    • Set 2>‘PC Callback’ to ‘Off’
    • Set 3>‘Encrypt Key 1’ as required
    • Set 4>‘Encrypt Key 2’ as required
    • Set 5>‘Listening Port’ to ‘n/a or None’
    • Set 6>‘Panel ID’ to ‘None’

    • Enter ‘Path Options’ menu
    • Enter ‘PSTN’
    • Set ‘Name’ to ‘PSTN’
    • Set ‘Line Fault’ as required
    • Set ‘Line Fault Delay’ to ‘0’
    • Set ‘Transmission Path’ to ‘PSTN’
    • Set ‘Dial Tone’ to ‘UK’
    • Set ‘Dialling’ to ‘DTMF’
    • Set ‘Ring Count’ to ‘1’
    • Set ‘Encryption’ to ‘No’
    • Exit Installer / Engineer Mode
    • Note: This may require a full panel and DualCom Pro reboot.