Panel Connection – Dial Capture
Manufacturer | Carrier |
Model | Aritech ATS Advanced |
Version | N/A |
Minimum Panel Firmware | N/A |
Cable required? |
MCM connected to
|
Panel Profile | ARITECH-ADVANCED-MCM |
Panel Bus Connection | Dial Capture |
Technical Notes |
To enter engineer mode, access must be allowed via a setting in User mode. After defaulting the panel, the panel will ask questions on power up. User Code : Menu 8:2:1 - Need Acc [YES] Eng Code : Menu 8: Sys Opt > 7: Panel & AB Opts > 9: Remote Config - YES |
Panel Connection Information
DualCom Pro 1 - MCM plug-on module - Line A DualCom Pro 2 - DI |
PSTN A |
DualCom Pro 1 - MCM plug-on module - Line B DualCom Pro 2 - AL |
PSTN B |
Panel Programming
- Enter : Installer Mode (Engineer)
- Select: 9>Dialler menu
- Enter: 1> CS
- Enter: 01> CS 1
- Set: CS name [CS 1]
- Enter: 2>‘Transm Path’ [PSTN]
- Enter 3>‘Protocol’
- Set: (X)SIA’
- Enter 4>Phone [01234567890]
- Enter 5>‘Accounts’ menu
- Select: ‘Area ‘1’ with [account numbers]
- Select: ‘Area ‘2’ with [account numbers OR blank]
- Select: ‘Area ‘3’ with [account numbers OR blank]
- Select: ‘Area ‘4’ with [account numbers OR blank]
- Enter 6>‘Mode’
- Set: Primary CS’
- Enter 7> retry count [10]
- Enter 8>‘Protocol opt’
- Set: ‘(X)SIA’
- Set ‘Area Modifier’ to ‘[ON]’
- Set ‘Name Chars’ to ‘[30]’
- Set ‘Event Number’ to ‘[3 digits]’
- Set ‘Subev codeing’ to ‘[Decimal]’
- Set ‘SIA Frequency’ to ‘[Bell]’
- Go back to ‘Dialler’ menu level
- Enter 3>‘Path Options’
- Enter 1>‘PSTN’
- Enter 2>‘Line Fault’ menu and select option ‘[No]’
- Go back to ‘Path Options’ menu level.
- Enter 4>IP (If present)
- Enter ‘Line Fault’ menu and select option ‘[No]’
- Enter 4>‘PC Conn’ menu
- Select 1>‘PC Conn 1’
- Set 2>‘Trans Path’ to ‘PSTN’
- Set 3>‘Modem Protocol’ to ‘V22’
- Set 4>‘Phone Number’ to ‘None’ or blank
- Set 5>‘Retry Timeout’ to ‘3’
- Set 2>‘PC Callback’ to ‘Off’
- Set 3>‘Encrypt Key 1’ as required
- Set 4>‘Encrypt Key 2’ as required
- Set 5>‘Listening Port’ to ‘n/a or None’
- Set 6>‘Panel ID’ to ‘None’
- Enter ‘Path Options’ menu
- Enter ‘PSTN’
- Set ‘Name’ to ‘PSTN’
- Set ‘Line Fault’ as required
- Set ‘Line Fault Delay’ to ‘0’
- Set ‘Transmission Path’ to ‘PSTN’
- Set ‘Dial Tone’ to ‘UK’
- Set ‘Dialling’ to ‘DTMF’
- Set ‘Ring Count’ to ‘1’
- Set ‘Encryption’ to ‘No’
- Exit Installer / Engineer Mode
- Note: This may require a full panel and DualCom Pro reboot.