Panel Connection – DC09

Manufacturer Alphatronics
Model Unii, XL and ML
Version DualCom Pro 2 v2.1.14 and above. Unii is not supported for DualCom Pro 1.
Minimum Panel Firmware XL from 315 / ML from V507
Cable required?

Ethernet Cable (CS.1.301)

Panel Profile DC09-SIA-IP
Panel Connection TCP/IP using IPv4
Technical Notes

DualCom Pro to Panel Wiring

The DualCom Pro can be powered from either OUT2 or OUT3 on the panel. It is recommended that the DualCom Pro is installed inside the panel to protect against tampering.

DualCom Pro Setup

The DualCom Pro is compatible with SIA DC-09-2021 and will transmit any SIA Alarms received, without modification, to the ARC.

The default values configured in the device are below and should be updated as appropriate:

Variable Value
IP Address DHCP
Subnet Mask DHCP
Default Gateway DHCP
DC09 Encryption Key

12345678123456781234567812345678

DualCom Pro DC09 IP Port 18000
DC09 Panel Timeout 95 seconds

Please contact CSL Technical Support who can assist in modifying the defaults if required.

Panel Setup

Unii Panel

Select IP Diallers

  • Dialler 1
    • Protocol: SIA DC09 unencrypted or SIA DC09 encrypted
    • Polling: Select DP 1 to DP4
    • Transmission: TCP
    • Message types to send to ARC
      • Select “Arm / disarm”
      • Select “Alarm”
      • Select “User action (Optional)”
    • Primary Dialler
      • Select: “Enabled”
      • Account number: enter ARC Connection ID
      • Receiver address: Enter the IP address of the DualCom Pro
      • Receiver port: 18000
      • Connection type: LAN
      • Polling interval: 30
      • SIA Test Report Code: RP
      • Test report interval (M): 1440

ML Panel

Select IP Diallers

  • IP dialler settings
    • Local port: 18000
    • Reports: All messages
    • Protocol: SIA DC 09 or SIA DC 09 encrypted
    • Connection type: Select DP1 to DP4
    • Transport protocol: TCP
  • Dialler 1 LAN
    • Select Active
    • Transmission path: LAN
    • IP address: Enter the IP address of the DualCom Pro
    • Account number: Enter the last 4 digits of the ARC connection ID
    • Port: 18000
    • Polling time: 30

XL panel

Select “IP Diallers”

Select tab sheet “DC09 / SecIP”

Diallers : Primary only

  • Protocol: SIA DC 09 or SIA DC 09 Encrypted
  • Connection type: Select DP1 to DP4
  • Transport protocol: TCP
  • IP address: Enter the IP address of the DualCom Pro
  • Account number: Enter the last 4 digits of the ARC connection ID
  • Port: 18000
  • Polling time: 30