Panel Connection – RS232
Manufacturer | Eaton |
Model | Scantronic/Menvier M-Series |
Version | M1000 and M2000 |
Minimum Panel Firmware | MIN V1:01 |
Cable required? | Menvier-M-RS232 |
Panel Profile |
MENVIER-M-RS232 |
Panel Bus Connection | Unterminated serial cable with 9 Way D-Type IDC socket |
Technical Notes |
See below |
Panel Connection Information
Connection | Panel |
RS232-T | 9 Way D-Type Pin 2 |
RS232-R | 9 Way D-Type Pin 3 |
RTN | 9 Way D-Type Pin 5 |
Panel Programming
- Go to Engineer Level 2
- Option 5 Communications
- Option 2 Digicom
- Option 1 Comms Format
- Set to Option 7 - Extended SIA level 3
- Option 2 ARC No 1
- Set telephone number to <01666111>
- Back to Digicoms option 2
- Option 3 for account numbers
- Enter the Account Number 1 <_______>
- Option 4 Dialling mode Should be set to - Consecutive -
- Option 5, Options
- Option 1 Restore signals select
- Option 2 Fast Format <8FF Channels>
- Back to Digicoms Option 2
- Option 6 CID/SIA reports set to [Full]
- Back to Engineer Level 2
- Option 5 Communications
- In Option 4 RS232 options
- Ensure Option 1 - Select RS232 baud <38400>
- And Option 2 - Select Remote Modem
- Back to Go to Engineer Level 2
- Option 5 Communications
- Select Option 1 downloader
- Enter Option 1 and Select Password <______> (same as configured in downloader application)
- Communications Option 5
- Select Option 1 - Downloader
- Set Option 3, Select access mode to - Unattended -
- Set Option 4, Edit call No 1 to - BLANK
- Option 5 Modem Options ensure
- Option 1 - Select rings to answer Option 1 is - Immediate
- Option 2 - Select baud rate - 1200 - (2400 if available)