Panel Connection – RS232

Manufacturer Eaton
Model Scantronic/Menvier M-Series
Version M1000 and M2000
Minimum Panel Firmware MIN V1:01
Cable required? Menvier-M-RS232
Panel Profile

MENVIER-M-RS232

Panel Bus Connection Unterminated serial cable with 9 Way D-Type IDC socket
Technical Notes

See below

Panel Connection Information

Connection Panel
RS232-T 9 Way D-Type Pin 2
RS232-R 9 Way D-Type Pin 3
RTN 9 Way D-Type Pin 5

Panel Programming

  • Go to Engineer Level 2
  • Option 5 Communications
  • Option 2 Digicom
  • Option 1 Comms Format
  • Set to Option 7 - Extended SIA level 3
  • Option 2 ARC No 1
  • Set telephone number to <01666111>
  • Back to Digicoms option 2
  • Option 3 for account numbers
  • Enter the Account Number 1 <_______>
  • Option 4 Dialling mode Should be set to - Consecutive -
  • Option 5, Options
  • Option 1 Restore signals select
  • Option 2 Fast Format <8FF Channels>
  • Back to Digicoms Option 2
  • Option 6 CID/SIA reports set to [Full]
  • Back to Engineer Level 2
  • Option 5 Communications
  • In Option 4 RS232 options
  • Ensure Option 1 - Select RS232 baud <38400>
  • And Option 2 - Select Remote Modem
  • Back to Go to Engineer Level 2
  • Option 5 Communications
  • Select Option 1 downloader
  • Enter Option 1 and Select Password <______> (same as configured in downloader application)
  • Communications Option 5
  • Select Option 1 - Downloader
  • Set Option 3, Select access mode to - Unattended -
  • Set Option 4, Edit call No 1 to - BLANK
  • Option 5 Modem Options ensure
  • Option 1 - Select rings to answer Option 1 is - Immediate 
  • Option 2 - Select baud rate - 1200 - (2400 if available)