Panel Connection – RS232
Manufacturer | RISCO |
Model | LightSYS |
Version | LightSYS, LightSYS II |
Minimum Panel Firmware | V1.62 |
Cable required? | RISCO LightSYS & Agility Cable CS.1.202 |
Panel Profile | RISCO-LITESYS-RS232 |
Panel Bus Connection | RS232 |
Technical Notes |
See troubleshooting below |
Panel Connection Information
Pin | SPT | Colour |
Pin 1 | T | Red |
Pin 2 | RTN | Blue |
Pin 3 | R | Yellow |
Panel Programming
- Login to Engineer Mode, exit/Menu Button, press Engineer Code and press OK
- [Keypad shows 1] Programming and press OK
- [Scroll to 1] System and press OK
- [Scroll ↓ to 2] Controls and press OK
- [Scroll ↓↓ to 3] Communication and press OK
- [Scroll ↓↓ to ARC ENABLE] and set to 'N' and press OK
- [Screen shows 3] Communication and press OK
- [Scroll ↓ to FM] Enable and set to 'N' and press OK
- [Screen shows 3] Communication and press OK
- [Scroll ↓↓ to CS ENABLE] and set to 'Y' and press OK
- Press Exit/Menu Button 2 twice you are now in the Main Menu
- [Scroll ↓↓↓ to 5] Communications and press OK
- [Scroll ↓ to 3] Config. SW and press OK
- [Screen shows 1] Security and press OK
- [Scroll ↓ to 2] Remote ID and press OK
- Modify value to 00000 and press OK
- [Screen shows 2] Remote ID Press Exit/Menu Button press ↓
- [Screen shows 2] Call Back. Press OK and ensure NO PHONE NUMBERS are set
- Press Exit/Menu Button x 4 times
- [Screen shows 5] Communication
- Now Exit/Engineer Mode 0 and press OK, this will save the data
Troubleshooting
- NOTE: RISCO LightSYS has two communication menus, please check you are in the correct
Communication Menu during panel programming. - Ensure upon initial panel start up that the language selection is used otherwise ARC Enable will
not show under Communications Menu 3. - To amend this, go to [Programming][System][Settings][Customer] and change it from ‘0EN’ to
‘0UK’ (as it should be for us in the UK). - By doing this, they will forfeit the entire programming as the panel will invoke a full default for
‘UK’ settings. - NOTE: Panel integration only supports non-zone type alarms such as BV (Burglary Verified) on the following – DualCom Pro V2.25 & up and DualCom Pro 2 all FW versions