Panel Connection – TTL
Manufacturer | Orisec |
Model | CP Range |
Version | CP-10 CP-20 CP-25 CP-30 W-CP-40 CP-50 CP-100 CP-200 |
Minimum Panel Firmware | CP-10 V1.00 CP-20 V1.00 CP-25 V1.10 CP-30 V3.10 W-CP-40 V1.42 CP-50 V1.84 CP-100 V1.84 CP-200 V1.84 |
Cable required? | Provided with DualCom Pro |
Panel Profile | Orisec-CP-TTL |
Panel Bus Connection | TTL |
Technical Notes | N/A |
Panel Connection Information
Manufacturer | Panel | Connection | Cable/Plug On | Supplied Cables |
Orisec | All | TTL | 4 Pin (cable provided) | Green - RTN Blue - TTL-T Red - TTL-R |
Panel Programming
- Enter “Engineering Mode” using the “Engineer Code”, followed by the “Manager
Code” - “Programming Menu” > Navigate to “ARC-Setup Menu” 17
Insert or Modify the following
- Account = ARC Account ID
- Protocol = SIA3 or Contact ID
- Dial Seq = 2
- Reported = Set triggers as required
- Area = Set areas as required
- IP Address = Clear value
- IP Port = Clear value
- Exit back to “Programming Menu”
- Select “Com Port Setup Menu” 13
Insert or Modify the following
- Com Port = 1
- Mode = DualCom Pro
- Exit “Engineering Mode”
Technical Notes
Line fault is through the serial interface, no extra settings are required in either the panel or the DigiAir/DualCom Pro