Panel Connection – TTL
Manufacturer | InnerRange |
Model | Inception |
Version | V0.0.0.2695.R0 |
Cable required? | InnerRange Product Code 9930360USB |
Panel Profile | INNERRANGE-INCEPTION-TTL |
Panel Bus Connection | TTL |
Technical Notes | USB cable will require the white connector plug removing |
Panel Connection Information
TTL | Green wire from USB Cable |
TTL R | White wire from USB Cable |
RTN | Black wire from USB Cable |
Panel Programming
- The panel is only configurable using the Web Interface. Therefore, an Ethernet cable must be plugged in the panel, and the engineer on site must have a laptop.
- On the supplied USB stick, run ‘Inception Discovery tool’ to find the panel on the network.
- Log in to the panel as installer. The default information is in the panel documentation
- Navigate to: Configuration > General > Alarm Reporting
- Within the alarm reporting menu, select ‘WebWayOne Configuration’
> This will drop down a list of options for WebWayOne Configuration
> Tick ‘Enable WebWayOne Reporting’ - Select your reporting type. Possible options are SIA and Contact ID
- Click save at the top of the screen.
- It is possible to send through a batch of alarms to test, by clicking the ‘Send All Possible Alarms’ button.