Panel Connection – TTL

Manufacturer InnerRange
Model Inception
Version V0.0.0.2695.R0
Cable required? InnerRange Product Code 9930360USB
Panel Profile INNERRANGE-INCEPTION-TTL
Panel Bus Connection TTL
Technical Notes USB cable will require the white connector plug removing

Panel Connection Information

TTL Green wire from USB Cable
TTL R White wire from USB Cable
RTN Black wire from USB Cable

Panel Programming

  • The panel is only configurable using the Web Interface. Therefore, an Ethernet cable must be plugged in the panel, and the engineer on site must have a laptop.
  • On the supplied USB stick, run ‘Inception Discovery tool’ to find the panel on the network.
  • Log in to the panel as installer. The default information is in the panel documentation
  • Navigate to: Configuration > General > Alarm Reporting
  • Within the alarm reporting menu, select ‘WebWayOne Configuration’
    > This will drop down a list of options for WebWayOne Configuration
    > Tick ‘Enable WebWayOne Reporting’
  • Select your reporting type. Possible options are SIA and Contact ID
  • Click save at the top of the screen.
  • It is possible to send through a batch of alarms to test, by clicking the ‘Send All Possible Alarms’ button.