Panel Connection – MCM
Manufacturer | Honeywell |
Model | Galaxy |
Version | 16/16+ |
Minimum DualCom Pro Firmware | DualCom Pro: V2.34 DualCom Pro 2: V2.1.1 |
Minimum Panel Firmware | Minimum V1.4 |
Cable required? | Normal Alarm Cable |
Panel Profile | Honeywell-Galaxy-MCM |
Panel Bus Connection | MCM |
Technical Notes | N/A |
Cable Connection
Pro | Panel |
MCM plug-on module - Line A | PSTN Line A |
MCM plug-on module - Line A | PSTN Line B |
Panel Programming - Digi
- Enter Engineer Menu 56
- Select Internal Telecoms (1) or Ext Telecoms (5) *
- Select format (Option 1)
- Enter SIA (Option 2)
- Select SIA level 3
- Ensure Trigger 10 is on
- Ensure Trigger 18 is on
- Select Tel No.1 (option 2)
- Set phone number 01234 567890
- Select Account Number (option 3)
- Enter <_____> (site ID)
- Go to remote Access (Option 12)
- Select Access Period
- Select Mode
- Escape to return to Engineering mode
- Exit Engineer Mode into Day Mode