Panel Connection – TTL
Manufacturer | HKC |
Model | SecureWave |
Version | 1070 |
Minimum Panel Firmware | V1, V2 |
Cable required? | CS.1.204 |
Panel Profile | HKC-SECUREWAVE-TTL |
Panel Bus Connection | TTL |
Technical Notes |
See below |
Panel Connection Information
Pin | SPT | Colour |
Pin 2 | R-TTL | Yellow |
Pin 3 | TTL-T | Black |
Pin 4 | RTN | Green |
Panel Programming
- Enter “Engineer” mode
- Make sure SP1 on the HKC panel is set up for Remote PC
- Enter “Communications” menu
- Communications Options Menu
- SP1 Port Options
- Set "Remote Access" to "Secure Access"
- Set "Local Access"
- Set "Printer Port"
- Make sure SP1 baud is set to 2400
- Data bits 8
- Stop bit 1
- NO PARITY (default)
- Go to "Communications” menu
- "Communication Service” menu
- "Port Settings"
- "Communications Service” menu
- To change remote user code from default
- Enter “Communications” menu
- Select “Remote User” menu
- Select “Remote User Code”
- RO1 Remote user will be displayed, set and verify this as 1234 or as required
- Notify CSL of the new code or set this using menu K on the DualCom Pro Communicator