Panel Connection – TTL
Manufacturer |
GSD |
Model |
GSDi-2-70-GSDi-10-70 |
Version |
DualCom Pro V2.15 |
Minimum Panel Firmware |
V2.12.43 |
Cable required? |
CS.1.208.01 |
Panel Profile |
GSD-GSD170-TTL |
Panel Bus Connection |
TTL |
Technical Notes |
Remote Manager Version - V3.3.2.0 - UDL Software Version V1.0.1.8
|
Panel Connection Information
Pin Out 1 |
Power and RTN |
Black Wire |
Pin Out 2 |
TTL-T |
Yellow Wire |
Pin Out 3 |
R-TTL |
Blue Wire |
Pin Out 4 |
+ Power |
Red Wire |
Panel Programming
- Panel default Installer code: 6666
- Panel default User 1 code: 1111
- Enter “Engineer Mode” on the panel using the engineer code
- Navigate to “Installer Menu” > “Communications” > “Alarm Rx Centres”
- Select “Communications” > “Alarm Rx Centres” > “Al. Rx. Centre 1” > enter “Menu”
- “Communications” > “Alarm Rx Centres” > “Al. Rx. Centre 1” > Name: Enter an ARC name
- “Communications” > “Alarm Rx Centres” > “Al. Rx. Centre 1” > “Account code” > Set the
account code to the ARC account code”
- “Communications” > “Alarm Rx Centres” > “Al. Rx. Centre 1” > “Format” > choose “Contact
ID” or “SIA”
- “Communications” > “Alarm Rx Centres” > “Al. Rx. Centre 1” > “Connection 1” > “Phone
number” and enter the # symbol
- “Communications” > “Alarm Rx Centres” > “Al. Rx. Centre 1” > “Events” > “Alarms” > Select
the types of alarms you wish to be reported to the ARC
- “Communications” > “Alarm Rx Centres” > “Al. Rx. Centre 1” > “Events” > “Other events” >
Select the other event types you would like to be reported to the ARC
Hints & Tips
A recommended minimal selection of Alarm Events would be: ‘Set and Unset’, ‘Inhibits and Overrides’, ‘Tampers’, ‘Mains Power Faults’ and ‘Battery Faults’.