Panel Connection – Dial Capture
Manufacturer | Generic |
Model | Dial Capture |
Version | N/A |
Minimum Panel Firmware | N/A |
Cable required? | MCM connected to
|
Panel Profile | GENERIC-ALARMS-MCM |
Panel Connection | Dial Capture |
Technical Notes |
|
DualCom Pro to Panel Wiring
DualCom Pro 1 - MCM plug-on module - Line A DualCom Pro 2 - DI |
PSTN A |
DualCom Pro 1 - MCM plug-on module - Line B DualCom Pro 2 - AL |
PSTN B |
Panel Configuration
Configure the panel according to the manufacturer’s panel guide, as if the panel was being connected to the PSTN.
We recommend a properly formatted telephone number be used in the ARC field. Any number will be accepted by the DualCom Pro.
We recommend using the Connection ID for the account number as this will be included in the SIA code sent to the ARC by the DualCom Pro.