Panel Connection – Telecoms Module RS485
Manufacturer | Honeywell |
Model | Galaxy |
Version | Dimension, G3, Classic |
Minimum Panel Firmware | (Min V1.4) |
Cable required? | Provided with DualCom Pro |
Panel Profile | Honeywell-Galaxy-PSTN-RS485 |
Panel Bus Connection | RS485 |
Technical Notes | N/A |
Panel Connection Information
Manufacturer | Panel | Connection | Cable/Plug On | Supplied Cables |
Honeywell | Galaxy G3/Dimension | Telecoms module | Lead provided with DualCom Pro or normal alarm cable | Green – RTN Blue – RS485 B Red – RS485 A |
Panel Programming
- Engineer Menu 56
- Select External Telecoms Module (Option 5)*
- Select Format (Option 1)
- Enter SIA (Option 2)
- Select SIA level 3
- Ensure Trigger 10 is on
- Ensure Trigger 18 is on
- Activate any further triggers which are required
- Select Tel No. 1 (Option 2)
- Set Phone number (01234 567890)
- Select Account Number (Option 3)
- Enter Site ID <_____> (Chip Number)
- Go to Remote Access (Option 12)
- Select Access Period
- Select Mode (Direct Access)
- Escape to return to Engineering mode
- Exit Engineering to find the Pro as a Comms module, we also emulate a
- Keypad, typically Comms Module 004 and Keypad 015 – varies between
panels
Galaxy Troubleshooting
- Menu 23: Panel Firmware Version
- Menu 62: Full Set inside Engineering
- Galaxy panels running version V1.4 and below cannot support SIA and are a
pins only integration - Panel Manufactures Default Codes - USER: 1234
- Panel Manufactures Default Codes - ENG: 112233