Panel Connection – RS232 connection via ATS7090 board

Manufacturer Carrier
Model ATS
Version Advanced
Minimum DualCom Pro Firmware DualCom Pro 2: v2.1.14 and ATS7090 version 2.02 or later.
Minimum Panel Firmware All versions greater and equal to 026.026.0141-0143
Cable required?
  • Ribbon cable (05-5042)
  • ATS7090 - Peripheral
Panel Profile ARITECH-ADVANCED-ATS7090
Panel Bus Connection RS232
Technical Notes When configuring the panel with a laptop, disconnect the ribbon cable between the Panel and DualCom Pro 2 before connecting the Laptop. When finished, you must disconnect the laptop and then reconnect the ribbon cable. ATS7090 Peripheral MUST be situated on AUX3.

IMPORTANT - The ribbon cable should be connected to the connector next to the RS232 terminals with the jumper on two pins farthest to the ribbon cable.

  • ATS7090 TX -> RX CSL Pro2
  • ATS7090 RX -> TX CSL Pro2

Panel Programming

  • Enter ‘Dialler’ menu [9]
  • Enter ‘CS 1’ menu [1]
  • Enter ‘Transm Path’ menu [2]
  • Select Option [‘TDA75XX’]
  • Enter ‘Protocol’ menu [3]
  • Select option [‘(X)SIA’]
  • Enter ‘Accounts’ menu
  • Select ‘Area N’ with [account numbers]
  • Enter [Mode] menu
  • Select option ‘Primary [CS]
  • Enter ‘Protocol Opt’ menu [8]
  • Enter [(X)SIA] menu
  • Set ‘Area Modifier' to [ON]
  • Set ‘Name Chars’ to [30]
  • Set ‘Event Number’ to [3 digits]
  • Set ‘Subev Codeing [to ‘Decimal]
  • Set [SIA Frequency] to [Bell]
  • Go back to [Dialler] menu level
  • Enter ‘Path Options’ menu [3]

Enter ‘Path Options’ menu [3]

  • Enter ‘PSTN’ menu [1]
  • Enter ‘Line Fault’ menu and select option [No]
  • Go back to ‘Path Options’ menu level.
  • Enter ‘IP’ menu [4] If present
  • Enter ‘Line Fault’ menu and select option [No]
  • Go back to 'Path options' menu level
  • Exit Installer (Engineer) mode
  • Enter 'TDA75XX' menu [7]
  • Enter 'Line Fault' menu and select option 'If used'
  • Go Back to Installer Menu level and select Menu 8: Sys Opt > 7: Panel & AB Opts > 9: Remote Config - YES
  • Exit Installer (Engineer) mode

Technical Notes

  • May require full panel and DC Pro power cycle
  • User Code: Menu 8:2:1 - Need Acc [YES]
  • The Area Account in the Alarm Events. This might need to be adjusted in the Panel's Settings in order to have a specific Area Number not a generic Account Number [Example: Area 1 - 0001, Area 2 - 0002, etc.....]