Panel Connection – DC09
Manufacturer | Alphatronics |
Model | Unii, XL and ML |
Version | |
Minimum Panel Firmware | XL from 315 / ML from V507 |
Cable required? |
Ethernet Cable (CS.1.301) |
Panel Profile | DC09-SIA-IP |
Panel Connection | TCP/IP using IPv4 |
Technical Notes |
DualCom Pro to Panel Wiring
The DualCom Pro can be powered from either OUT2 or OUT3 on the panel. It is recommended that the DualCom Pro is installed inside the panel to protect against tampering.
DualCom Pro Setup
The DualCom Pro is compatible with SIA DC-09-2021 and will transmit any SIA Alarms received, without modification, to the ARC.
The default values configured in the device are below and should be updated as appropriate:
Variable | Value |
IP Address | DHCP |
Subnet Mask | DHCP |
Default Gateway | DHCP |
DC09 Encryption Key |
12345678123456781234567812345678 |
DualCom Pro DC09 IP Port | 18000 |
DC09 Panel Timeout | 95 seconds |
Please contact CSL Technical Support who can assist in modifying the defaults if required.
Panel Setup
Unii Panel
Select IP Diallers
- Dialler 1
- Protocol: SIA DC09 unencrypted or SIA DC09 encrypted
- Polling: Select DP 1 to DP4
- Transmission: TCP
- Message types to send to ARC
- Select “Arm / disarm”
- Select “Alarm”
- Select “User action (Optional)”
- Primary Dialler
- Select: “Enabled”
- Account number: enter ARC Connection ID
- Receiver address: Enter the IP address of the DualCom Pro
- Receiver port: 18000
- Connection type: LAN
- Polling interval: 30
- SIA Test Report Code: RP
- Test report interval (M): 1440
ML Panel
Select IP Diallers
- IP dialler settings
- Local port: 18000
- Reports: All messages
- Protocol: SIA DC 09 or SIA DC 09 encrypted
- Connection type: Select DP1 to DP4
- Transport protocol: TCP
- Dialler 1 LAN
- Select Active
- Transmission path: LAN
- IP address: Enter the IP address of the DualCom Pro
- Account number: Enter the last 4 digits of the ARC connection ID
- Port: 18000
- Polling time: 30
XL panel
Select “IP Diallers”
Select tab sheet “DC09 / SecIP”
Diallers : Primary only
- Protocol: SIA DC 09 or SIA DC 09 Encrypted
- Connection type: Select DP1 to DP4
- Transport protocol: TCP
- IP address: Enter the IP address of the DualCom Pro
- Account number: Enter the last 4 digits of the ARC connection ID
- Port: 18000
- Polling time: 30